Sealand DTD02 Discharge Pump Control Manual de usuario Pagina 8

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 7
8
Dometic Tank Discharge ControlIntended use
3.2 OPTION 2: DTD02 discharge control panel with DTM04 tank monitor system
WhenintegratedwiththeDometicDTM04TankMonitorSystem,theDTD02TankDischargeControl
panel will automatically shut off the discharge pump when the holding tank is empty.
Caution!
Operator must know local regulations for emptying a holding tank.
Note
TheUSCoastGuardallowsakey-operatedswitchasameanstosecureanoverboard
dischargepumpsystem.TurnoffDTD02systemandremovekeyfromswitchwhenboating
in“NoDischarge”waters.
3.3 Features
Secure discharge pump control. Key-operated switch provides convenient means to secure
discharge pump operation without use of padlocks or other mechanical fasteners.
Helps prevent pump burn-out. Activatedpanellightindicateswhendischargepumpisoperating.
Reminds operator to shut off pump when tank discharge is complete.
Prevents potential damage from discharging tank against closed seacock. Activatingadischarge
pump while seacock is closed can cause pressure build-up in discharge hose which may damage
pumporboatandresultincostlyrepairs.Theseacockinterlockswitch(availableseparately)greatly
reduces this possibility.
Automatic pump shut-off with DTM04 tank monitor system. Dischargepumpstopswhentank
leveldropsbelow“empty”levelprobe(g.
6
C,page4).
Simplifies plumbing system. Eliminates wye valves and vented loops of multi-toilet systems.
4 Specifications
4.1 Materials
Panel frame and mounting frame:ABS Panel surface: Polycarbonate resin
Circuit assembly housing: High-density polyethylene
4.2 Electrical current draw (panelonly)
System Voltage Pump Off (amp) Pump On (amp)
12VDC 0 0.16
24VDC 0 0.095
Specications subject to change without notice.
Maximumrelayratingfor12or24VDCdischargepump:20amps.
FloatSwitchRating:20wattswithresistiveload(whenusedwithDTM04system).
4.3 Dimensions (g.
3
,page2)
Ref. Dimension
A 3.25 in. / 83 mm
B 3.25 in. / 83 mm
Ref. Dimension
C 51 mm / 2 in. clearance behind wall
D 0.38 in. / 10 mm
Vista de pagina 7