Sealand DTD02 Discharge Pump Control Manual de usuario Pagina 7

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 6
7
EN
Table of contents
1 Notes on using the manual .................................................7
2 General safety instructions .................................................7
3 Intended use .........................................................7 - 8
4 Specications ........................................................8 - 9
5 Components ............................................................9
6 Installation ..........................................................9 - 10
7 Operation..............................................................11
8 Warranty ..........................................................12 - 13
9 Customer service........................................................13
Dometic Tank Discharge Control Notes on using the manual
1 Notes on using the manual
Caution!
Safety Instruction: Failure to observe this instruction can cause material damage and impair
the function of the device.
Note
Supplementary information for operating the device.
g.
1
2, page 2 : This refers to an element in an illustration. In this example, item 2 in gure
1 on page 2.
2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
• Faultyinstallationorconnection
• Damagetotheunitfrommechanicalinuences,misuseorabuse
• Alterationstotheunitwithoutexpresswrittenpermissionfromthemanufacturer
• Useforpurposesotherthanthosedescribedinthismanual
3 Intended use
3.1 OPTION 1: DTD02 discharge control panel only
DTD02TankDischargeControlpanelprovidesakey-operatedswitchtoactivateadischargepump
thatwillemptyaholdingtank.Agreenlightindicateswhenthedischargepumpisoperating.The
DTD02canbeusedwithvirtuallyanyelectricdischargepumpthatoperatesonthesamerated
voltage(12VDCor24VDC)andamaximumcircuitbreakerorfuseratingof20amps.
Because attempting to pump-out a holding tank can be harmful if the seacock to the overboard
dischargettingisclosed,theDTD02panelalsoincludesayellowwarninglightthatindicateswhen
theseacockisclosed.TheDTD02panelconnectstotwoDometicseacockswitches(available
separately):
• 385310675-seacockinterlockswitchandrelayforConbraco7014701
• 385310705-seacockinterlockswitchandrelayforGrocoBV1500
Vista de pagina 6