Sealand DTD02 Discharge Pump Control Manual de usuario Pagina 10

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 9
10
Dometic Tank Discharge ControlInstallation
6.2 Key to DTD02 - discharge pump system wiring
(g.
5
,page3)
Ref. Description
A DTD02controlpanel
B Dischargepump
C Seacock interlock switch
D 12or24VDC
E VDCground
Ref. Description
F Dischargepumpcircuitbreakerorfuse
G Red
H Black
I Brown
J White
1. HeavylinesinwiringdiagramrepresentstrandedcopperwiretobesizedaccordingtoABYCrecommendations.
2. Other wire can be 18 gauge stranded copper wire or larger.
3. Maximum discharge pump circuit breaker or fuse rating: 20 amps.
6.3 Key to DTD02-DTM04 system wiring (g.
7
,page4)
Ref. Description
A DTD02controlpanel
B Dischargepump
C DTM04indicatorpanel
D Wastewater tank
E 12or24VDC
F VDCground
G Dischargepumpcircuitbreakerorfuse
H 12VDC
I 24VDC
J 1-amp circuit breaker or fuse
K Toilet system circuit breaker or fuse
L +VDCtoelectrictoiletsystem
Ref. Description
M Full level probe
N Mid level probe
O Low/Empty level probe
P Red
Q Black
R Brown
S Green
T Blue
U Yellow
V Orange
W White
X Seacock interlock switch
1. Heavy line indicates 14 gauge or larger stranded copper wire is required.
2. Other wire can be 18 gauge stranded copper wire or larger.
3. Maximum discharge pump circuit breaker or fuse rating: 20 amps.
Vista de pagina 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 16

Comentarios a estos manuales

Sin comentarios