2 General safety instructions
The manufacturer will not be held liable for claims for damage resulting from the following:
Faulty assembly or connection
Damage to the unit from mechanical inuences, misuse or abuse
Alterations to the unit without express written permission from the manufacturer
Use for purposes other than those described in the operating manual
Dometic Tank Monitor General safety instructions
3 Intended use (g. , page 2)
DTM01C Tank Monitor panel indicates when a wastewater holding tank is almost full. This monitor helps
prevent damage to the boat that can happen because of accidental overlling of the holding tank.
Caution!
Operator must know local regulations for emptying a holding tank.
4 Components and Functions
Probe Cap with Float Switch
The probe cap installs into a threaded 3-inch (76 mm) FPT opening on the top of a Dometic
®
holding
tank or other holding tank equipped with such an opening. As the level of holding tank contents
rises, the oat switch inside the tank is pushed upward and activates the “Full Tank” light on the
indicator panel.
Indicator Panel
The indicator panel has a single light which is activated by the oat switch inside the holding tank.
When the “Full Tank” light is activated, the operation of any plumbing xture connected to the
holding tank should stop until the tank is emptied.
1
Items in fig. , page 2 Description
1 Probe cap with float switch
2 Indicator panel
3 #6 fasteners
2
5 Specifications
5.1 Materials
Average current consumption: 0.016 amps at 12 V DC. Requires 0.5-amp fuse.
5.2 Electrical Current Draw
ISO8846; EMC Directive 2004/108/EC
5.3 Approvals
Panel frame: ABS
Panel: Polyester
Probe cap: PVC
Float switch: Nitrile rubber ebonite