Sealand DTM04 Tank Monitor System Manual Manual de usuario Pagina 9

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 8
9
1. Select panel location away from direct contact with water
and oil.
2. Conrm clearance for wire connections behind wall, hull liner
or bulkhead.
3. Usingcontrolpaneltemplate(g.8,page5),cutout
panelaccesshole(E,F)anddrillfastenerholes(G).
4. With electrical power off, route 18-gauge stranded copper
wirefrompowersource,throughcircuitbreakerorfuse(not
provided),topanellocation.Routeadditionalwireaccording
todiagram(g.4,page3–seewiringdiagramkey
below),dependingonyourapplication,topanellocation.
Make sure wires extend out through access hole.
5. Make proper wiring connections to wires extending from
bottomofcircuitpanel(g.3A2,page3).
6. Removepanelcover(g.3A1,page3)fromcircuitpanel/
mountingframe(A2),ifnecessary,bycarefullypullingthem
apart.
7. Installmountingframetowallwithfourfasteners(g.3A3).
8. Push panel cover onto mounting frame until it locks into
place.
1. Atstep4(above),routeandconnect14-gaugestrandedcopperwiresaccordingtowiringdiagram
(g.4,page3)andwiringdiagramkey(seebelow).
2. Insert “Full Tank” shut-down relay into receptacle on back of circuit panel.
6.1 Tank Monitor Panel (g.3A,page2)
6.2 “Full Tank” Shut-down Relay (optional accessory) (g.14,page2)
DTM04 Panel Template
Dimensions (g.x,page5)
3
1
Dometic Tank Monitor System Specifications
Caution!
Do not install DTM04 panel in an atmosphere with potentially flammable or
explosive vapors.
Ref. Dimension
A 83mm/3.25in.
B 83mm/3.25in.
C 67mm/2.63in,
D 67mm/2.63in.
E 55mm/2.16in.
F 68mm/2.69in.
G 2mm/0.10in.dia.
H Cut-out area.
Allow51mm/2in.
clearance behind wall.
6
6
4
4
4
3
3
3
5.3 Dimensions (g.2,page2)
5.4 Approvals
ISO8846;EMCDirective2004/108/EC
Ref. Dimension
A 83mm/3.25in.
B 83mm/3.25in.
C 51mm/2in.clearancebehindwall
D 10mm/0.38in.
2
Ref. Dimension
E 111mm/4.375in.
F 25mm/1.0in.
G 527mm/20.75in.
H 69mm/2.75in.
6 Installation
Vista de pagina 8
1 2 3 4 5 6 7 8 9 10 11 12 13 14 ... 71 72

Comentarios a estos manuales

Sin comentarios

Pyle FM-Sender Benutzerhandbücher

Beginnend mit P

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
PLMP3C1
Bedienerhandbuch   Pyle PLMP3C1 FM transmitter, 3 Seiten
PLMP3C31B
Bedienerhandbuch   Pyle PLMP3C31B, 3 Seiten
PLMP4C4
Bedienungsanleitung   Pyle PLMP4C4 FM transmitter, 8 Seiten