9
1. Select panel location away from direct contact with water
and oil.
2. Conrm clearance for wire connections behind wall, hull liner
or bulkhead.
3. Usingcontrolpaneltemplate(g.8,page5),cutout
panelaccesshole(E,F)anddrillfastenerholes(G).
4. With electrical power off, route 18-gauge stranded copper
wirefrompowersource,throughcircuitbreakerorfuse(not
provided),topanellocation.Routeadditionalwireaccording
todiagram(g.4,page3–seewiringdiagramkey
below),dependingonyourapplication,topanellocation.
Make sure wires extend out through access hole.
5. Make proper wiring connections to wires extending from
bottomofcircuitpanel(g.3A2,page3).
6. Removepanelcover(g.3A1,page3)fromcircuitpanel/
mountingframe(A2),ifnecessary,bycarefullypullingthem
apart.
7. Installmountingframetowallwithfourfasteners(g.3A3).
8. Push panel cover onto mounting frame until it locks into
place.
1. Atstep4(above),routeandconnect14-gaugestrandedcopperwiresaccordingtowiringdiagram
(g.4,page3)andwiringdiagramkey(seebelow).
2. Insert “Full Tank” shut-down relay into receptacle on back of circuit panel.
6.1 Tank Monitor Panel (g.3A,page2)
6.2 “Full Tank” Shut-down Relay (optional accessory) (g.14,page2)
DTM04 Panel Template
Dimensions (g.x,page5)
3
1
Dometic Tank Monitor System Specifications
Caution!
Do not install DTM04 panel in an atmosphere with potentially flammable or
explosive vapors.
Ref. Dimension
A 83mm/3.25in.
B 83mm/3.25in.
C 67mm/2.63in,
D 67mm/2.63in.
E 55mm/2.16in.
F 68mm/2.69in.
G 2mm/0.10in.dia.
H Cut-out area.
Allow51mm/2in.
clearance behind wall.
6
6
4
4
4
3
3
3
5.3 Dimensions (g.2,page2)
5.4 Approvals
ISO8846;EMCDirective2004/108/EC
Ref. Dimension
A 83mm/3.25in.
B 83mm/3.25in.
C 51mm/2in.clearancebehindwall
D 10mm/0.38in.
2
Ref. Dimension
E 111mm/4.375in.
F 25mm/1.0in.
G 527mm/20.75in.
H 69mm/2.75in.
6 Installation