7
6 Installation
Caution!
DonotinstallDVS01panelinareawithpotentiallyammableorexplosivevapors.
1. Select panel location away from direct contact with water and oil.
2. Conrm clearance for wire connections behind wall, hull liner or bulkhead.
3. UsingDVS01paneltemplate(g.
7
, p. 11), cut out panel access hole and drill fastener holes.
4. Removepanelcover(g.
1
1,p.2)frommountingframe(3),ifnecessary,bycarefullypullingthem
apart. Install mounting frame to wall with four fasteners.
5. Withelectricalpoweroff,routeproperwiringtoDVS01panellocation,makingsurewiresextend
outthroughaccesshole(g.
1
4,p.2).Refertowiringdiagrams(gs.
4
and
5
, p. 3,
g.
6
, p. 4) for appropriate toilet system. Make nal wiring connections.
6. Push panel cover onto mounting frame until it locks.
7. TurnonelectricalpowertoDVS01panelandtoiletsystem.Conrmnormaloperationofstatus
lights.
7 Operation
7.1 Vacuum status monitor (g.
3
, p. 2)
1. WhenpowerswitchisturnedON,thegreen light indicates that there is sufcient vacuum in the
VacuFlushsystemtoushthetoilet(A).
2. WhenpowerswitchisturnedONandthered light glows, this indicates that there is NOT sufcient
vacuuminthesystemtoushthetoilet(B).Do not flush toilet, or blockage may occur in system.
Notes
Ifgreenandredlightconstantlycycleonandoffbetweenushes,thereisapossible
vacuumleakinthesystem.(AnidleVacuFlushsystemshouldnotcyclemorefrequently
than once every three hours.)
If green light is ON but there is no vacuum in system, a blockage has likely occurred
betweenthetoiletandvacuumtank.Openushballintoiletbowlandusestandardtoilet
plunger to unblock.
After a period of time, if red light seems to remain lit longer than when toilet system was
new,duckbillvalvesinvacuumpumpmayrequirereplacement.
Caution!
IfDVS01isconnectedtoa“fulltank”sensorandholdingtankisempty,acontinuousred
light may indicate extensive vacuum loss due to blockage, pump failure or leak. Turn off
vacuum system and repair as soon as possible.
7.2 “Full tank” monitor (whenconnectedto“fulltank”sensorinwasteholdingtank)
WhenpowerswitchisturnedON,theredlightglows,andthevacuumpumpisnotrunning,this
indicates that the holding tank is full and needs to be pumped out. Do not flush toilet, or blockage may
occur in system.
SeaLand DVS01 Panel Specifications