Sealand TankWatch 4 Level Monitoring System Manual de usuario Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 9
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
4
INSTALLATION INSTRUCTIONS
CONTROL PANEL
1. Select a mounting location away from direct contact with water and oil. Dry locations in the bathroom,
salon or galley are most desirable.
2. Conrmclearancesforthepanelbehindwalls,hulllinerorbulkhead.
3. Cutoutmountingholeforcontrolpanel.(Seetemplateforcut-outandholelocations.)
4. Donotmountthecontrolpaneluntilwiringisroutedandsecuredtotheterminalblockorrearofthe
control panel housing.
5. Routewiringfollowingoneofthewiringdiagramsforblack,grayorfreshwaterapplications.
6. Include wiring for any of the optional electrical accessories that may be part of the installation and shown
in separate wiring diagrams.
7. Mountthecontrolpanelwiththefour(4)#6x1-inchlongblack,oval-headscrewsprovided.
8. Determinewhichtankapplicationthecontrolpanelwillbemonitoringandinserttheappropriatecolor
light and matching lens into the correct location following the chart below.
Waste(Black)Water
Gray Water
Fresh Water
Green
Green
Red
Yellow
Yellow
Amber
Amber
Amber
Yellow
Red
Red
Green
Tank Application
Light & Lens Color Location
Empty
Low
Mid
Full
ADJUSTABLE LEVEL INDICATOR CAP
1. TheTankWatch
®
4levelindicatorcapisdesignedfora3-inchFPTopening.Orderpartnumber230272iftank
ismadeofrigidmaterialandisnotaSeaLandholdingtank.
2. Loosencompressionnutsonadjustableprobesandinstallthecapintothetank.Slidethe#1probedownuntil
theoattouchesthebottomofthetank.Tighten#1compressionnutandmarktheprobeatthetopofthenut
withapenorpencil.Donotcuttheprobe’stubingatthismark.Loosenthecompressionnut,slide
theprobeup,andcarefullycutthe#1probe’stubing1-5/8inch(41.3mm)belowthemarkwithoutdamaging
theswitchwires.Pullthewiresthroughtheblackwirecoverandpushtheprobedownintothecompressionnut
untiltheblackwirecovertouchesthecompressionnut.
3. Removecapfromtankandadjustthe#2probefor1/2fulllevelforgrayandblackwatertanksor1/4fulllevel
forfreshwatertanks.Tightenthecompressionnutandcuttheprobe’stubingoff3/8-inch(9.5mm)abovethe
compressionnutwithoutdamagingtheswitchwires.Sliptheblackwirecoverontothetopofthestem.
4. Tomakethe#1oatswitchactivatethe“Empty”light,theoatmustbepositionedwiththerecessedshoulder,
whiteband,ortheletters“NO”atthebottom.RemovetheC-clipfromtheswitchbody,iptheoat180de
-
grees,andreplacetheC-clip.(SeeDiagram#1.)
5. The#2oatswitchcanactivatethe“Mid”lightonblackandgraywatertanksandactivatethe“Low”lighton
freshwatertanks.Therecessedshoulder,whiteband,ortheletters“NO”shouldbefacingupforblackand
graywatertanksanddownforfreshwatertanks.(SeeDiagram#2.)
6. Route18-gaugestrandedcopperwirefromtheindicatorpaneltothelevelindicatorcap.Usequick-discon
-
nectterminalsonoatswitchwirestopreventtwistingwireswhenremovingthecap.Withcapremovedfrom
thetank,connectthewiresaccordingtothewiringdiagramandtesttheoatsbymovingthemupanddown.
DisconnectthewiresandinstallthecapwiththeO-ringintothetank,thenreconnectthewires.
7. Forcapswithvents,route5/8-inchventhosefromthethrough-hullttingtotheventconnectiononthelevel
indicator cap. Use stainless steel hose clamps to secure the vent hose connections.
Vista de pagina 3
1 2 3 4 5 6 7 8 9

Comentarios a estos manuales

Sin comentarios